Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add filters








Year range
1.
Arq. bras. med. vet. zootec. (Online) ; 70(2): 429-436, mar.-abr. 2018. ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-910399

ABSTRACT

Foram utilizados 30 cães neurologicamente saudáveis e realizadas radiografias da coluna cervical, sendo mensurada a menor distância atlantoaxial dorsal e outros parâmetros anatômicos vertebrais. Esses dados foram avaliados por meio do coeficiente de correlação de Pearson. Após detecção do melhor parâmetro de correlação, utilizou-se a fórmula de coeficiente de correlação dimensional (CCD). Na segunda etapa desta pesquisa, foram utilizadas imagens radiográficas de 33 cães com subluxação atlantoaxial (SAA) e aplicou-se a fórmula CCD. Todas as imagens atlantoaxiais normais e subluxadas foram distribuídas aleatoriamente e submetidas à análise subjetiva. Observou-se que o parâmetro anatômico de maior correlação foi o comprimento do processo espinhoso do áxis, obtendo-se valor de índice médio de 0,056 e desvio-padrão de 0,019. O valor de índice médio obtido em cães com SAA foi de 0,287, e o desvio-padrão de 0,123. A análise subjetiva revelou acerto de 88,89% a 95,24%, enquanto a avaliação por meio da fórmula CCD demonstrou ser 100% eficiente no diagnóstico da SAA. Sugeriu-se a utilização da fórmula CCD para obtenção do índice de normalidade da distância atlantoaxial com valor de normalidade médio de 0,056 e limite máximo de 0,098, sendo esse índice eficaz no diagnóstico da subluxação entre o atlas e o áxis.(AU)


Thirty healthy dogs had their cervical spines radiographed, and the dorsal atlantoaxial distance and others vertebral anatomical parameters were measured. These data were assessed using the Pearson correlation coefficient. After detection of the best correlation parameter, we used the dimensional correlation coefficient of formula (CCD). In the second stage of the study, radiographs of the 33 dogs with atlantoaxial subluxation (SAA) were used. In each radiographic image, the CCD formula was applied. All normal and subluxation radiographic images were randomized, and submitted to subjective analysis. It was observed that the anatomical parameter with the highest correlation is the length of the spinous process of the axis, obtaining a mean value of 0.056 index and 0.019 standard deviation. Index mean value obtained in dogs with the disease of 0.287 and standard deviation of 0.123. The subjective analysis revealed 88.89% to 95.24% agreement, while the result obtained by the CCD formula was shown to be 100% effective in the diagnosis of SAA. We suggest the use of the CCD formula to obtain the index of normality of the atlantoaxial distance with a mean value of 0.056 and maximum of 0.098, and it is concluded that the index is highly effective in the diagnosis of subluxation between the atlas and the axis.(AU)


Subject(s)
Animals , Dogs , Atlanto-Axial Joint/abnormalities , Dogs/abnormalities , Joint Dislocations/veterinary , Neurology
2.
Arq. bras. med. vet. zootec. (Online) ; 70(6)nov.-dez. 2018. ilus, graf, tab
Article in Portuguese | LILACS, VETINDEX | ID: biblio-970336

ABSTRACT

Objetivou-se com este trabalho comparar biomecanicamente os posicionamentos dorsal e medial da placa bloqueada na artrodese do carpo em cães. Para isso, foram utilizados sete pares de membros torácicos de cães eutanasiados por razões não relacionadas ao estudo, em que sete membros foram estabilizados com placa dorsal, e seus respectivos pares com placa em posicionamento medial. Os membros com as articulações radiocarpometacarpianas estabilizadas cirurgicamente foram submetidos a ensaio de compressão axial em máquina universal de ensaios de materiais, e os dados de limite de elasticidade, rigidez estrutural, carga máxima e carga no momento da fratura dos posicionamentos foram comparados por meio do teste de Student-Newman-Keuls, a um nível de significância de 5%. Todos os membros foram fraturados no terço distal do terceiro metacarpo; nos membros com placa dorsal, a fratura ocorreu distal ao orifício distal e, nos membros com placa medial, a fratura ocorreu no último orifício dos metacarpos dois e três. Não houve dobra ou quebra de placas e parafusos e não houve diferença significativa entre os posicionamentos dorsal e medial dos implantes quanto aos parâmetros avaliados.(AU)


The aim of this study was to compare biomechanically the dorsal and medial positions of the locking plates on carpal arthrodesis in dogs. For this, seven pairs of thoracic limbs of dogs were used, in which seven limbs were stabilized with dorsal plate and seven limbs with plate in medial positioning. The members with the surgically stabilized radiocarpal-metacarpal joints were submitted to axial compression testing in a universal testing machine and the yield load, structural rigidity, maximum load and ultimate load of the positioning were compared by Student-Newman-Keuls test at a significance level of 5%. All members fractured in the distal third of the third metacarpal, in the limbs with dorsal plate the fracture occurred distal to the distal hole and in the members with medial plate the fracture occurred in the last hole of the metacarpals two and three. There was no bending or broken implants. There was no significant biomechanical differencebetween the dorsal and medial positions of the implants.(AU)


Subject(s)
Animals , Dogs , Arthrodesis/veterinary , Biomechanical Phenomena , Dogs/abnormalities
3.
Arq. bras. med. vet. zootec. (Online) ; 69(6): 1473-1479, nov.-dez. 2017. tab
Article in English | LILACS, VETINDEX | ID: biblio-910164

ABSTRACT

The objective of the present study was to evaluate if extradural contact during hemilaminectomy would cause neurological deterioration in the early and/or late postoperative period in dogs with intervertebral disc extrusion. Nineteen dogs with thoracolumbar intervertebral disc extrusion underwent hemilaminectomy for spinal cord decompression and removal of extruded disc material. Meningeal contacts during surgery were quantified. Paraplegia (with nociception) and paraparesis were observed in 11/19 and 8/19 of dogs, respectively, before surgery. At the end of our study, only two (2/19) had paraplegia and one (1/19), paraparesis. There were more extradural contacts when extruded intervertebral disc material was at a ventrolateral position. Extradural contacts during surgery had no influence on neurological progression nor on time to recovery of motor function. Immediately (24 and 48 hours) after surgery, 13/19 dogs had the same neurological stage before surgery. At 7 and 90 days, 13/19 and 17/19 dogs, respectively, showed neurological improvement, compared with their preoperative stage. There was no influence of the number of extradural contacts on neurological recovery. These findings indicate that a careful inspection of the vertebral canal for removal of as much extruded disc material as possible does not cause neurologic deterioration.(AU)


O presente trabalho teve como objetivo avaliar se contatos extradurais durante hemilaminectomia em cães com extrusão de disco intervertebral causariam piora neurológica no pós-operatório imadiato e/ou tardio. Dezenove cães com extrusão toracolombar de disco intervertebral foram submetidos à hemilaminectomia para descompressão medular e remoção do material extruso. Durante o procedimento cirúrgico, os contatos meningomedulares foram quantificados. Antes da cirurgia, 11/19 cães apresentavam paraplegia (com nocicepção) e 8/19 cães, paraparesia. Ao fim do estudo, apenas dois cães (2/19) mostravam paraplegia com dor profunda e um (1/19), paraparesia. Observou-se maior quantidade de contatos extradurais quando o material discal extruso encontrava-se em posição ventrolateral. Os contatos extradurais não mostraram influência estatística na evolução neurológica dos animais, bem como no tempo de recuperação das funções motora. Vinte e quatro e 48 horas após a cirurgia, 13/19 cães apresentavam o mesmo grau neurológico de antes da cirurgia. Após sete e 90 dias de pós-operatório, 13/19 e 17/19 demonstraram melhora neurológica em comparação com o pré-operatório, respectivamente. A quantidade de contatos extradurais não influenciou na recuperação neurológica dos cães. Esses achados indicam que uma inspeção minuciosa do canal vertebral pode ser recomendada, a fim de remover o máximo de material discal extruso, evitando-se piora neurológica por compressão medular.(AU)


Subject(s)
Animals , Dogs , Decompression, Surgical/veterinary , Intervertebral Disc Displacement/surgery , Intervertebral Disc Displacement/veterinary , Spinal Cord/surgery
4.
Arq. bras. med. vet. zootec. (Online) ; 69(4): 933-940, jul.-ago. 2017. ilus, tab
Article in Portuguese | LILACS, VETINDEX | ID: biblio-876687

ABSTRACT

Fraturas costumam ocorrer com encavalgamento das extremidades ósseas, dificultando, assim, sua redução. Esta pesquisa teve como objetivo desenvolver um equipamento de tração esquelética a ser utilizado em caninos acometidos de fraturas de ossos longos. Foram utilizados 21 cães de raças variadas, pesando entre dois e 27kg, com idade entre dois meses e 11 anos, com fraturas diafisárias ou metafisárias ocorridas entre três e 24 dias. Enquanto a fixação do corpo do paciente à mesa foi efetuada com cintas de náilon, a força de tração aplicada ao longo do eixo ósseo do membro fraturado foi realizada mediante cintas de náilon ou pinos transfixados e estribos (sendo os pinos implantados na epífise distal do osso fraturado), com a força de tração medida por um dinamômetro, não sendo aplicada carga maior que 25kg. Em todos os casos, a força de tração iniciava com o valor de cinco quilogramas, exceto em animais com peso inferior a esta, a qual começava com carga equivalente a esse peso; e em todos, se necessário, era aumentada a cada cinco minutos para se manter tração igual ao peso ou aos valores que oscilavam do seu peso até cinco quilogramas, dependendo do tamanho do animal, até se atingir a tração necessária para se proceder à redução. Para essa progressão de distensão, o equipamento possuía haste rosqueada de 25mm de diâmetro, uma porca com sistema timão e cilindro deslizante por fora da haste, este conectado ao animal por uma corrente, e o dinamômetro. Todos os animais tiveram as fraturas reduzidas sem haver perda óssea, o que evidencia que o aparelho se mostrou eficiente tanto na redução como na manutenção da redução da fratura, e eles não apresentaram, no pós-operatório, sinais de prejuízos neurológicos, vasculares, cutâneos e articulares. O distensor ósseo aqui desenvolvido tem como características: ser de simples confecção, ter baixo custo, não gerar danos ao paciente e facilitar a redução dos fragmentos tanto em fraturas recentes quanto em antigas.(AU)


Fractures usually occur with overriding of bone fragments, thus hindering fracture reduction. The aim of this research was to develop and test a skeletal traction device for use in dogs with long bone fractures. Twenty-one dogs were included, regardless of breed or gender, weighing between two and 27kg, and between two months and 11 years of age, with metaphyseal or diaphyseal fractures that had occurred between three and 24 days prior to intervention. While fixation of the patient's body to the table was performed using nylon straps, the traction force applied along the bone axis of the fractured limb was performed using nylon straps or transfixed pins and stirrups (with the pins implanted in the distal epiphysis of the fractured bone). Tensile strength was measured by a dynamometer, and the maximum load applied was no greater than 25kg. In all cases, the distraction force began at five kilograms except in dogs below this weight, where the starting load was equivalent to the weight of the animal. If necessary, in all dogs, force was increased every five minutes to maintain equal traction to the dog's weight or values which ranged from the dog's weight to five kilograms depending on the size of the animal, until the necessary traction for reduction was obtained. For this progression of distension, the equipment had a 25-milimeter-diameter threaded rod, a nut with a rudder system and sliding cylinder outside the rod, which connected to the dog via a chain and the dynamometer. Fracture reduction was achieved in all dogs without bone loss, and the device was shown to be efficient in both allowing and maintaining fracture reduction, with no neurologic, vascular, cutaneous, or articular damage. The developed bone distractor has the following characteristics: simple to construct, low cost, does not harm the patient, and facilitates reduction of the fragments in recent and old fractures.(AU)


Subject(s)
Animals , Dogs , Fractures, Bone/veterinary , Orthopedic Equipment/statistics & numerical data , Orthopedic Equipment/veterinary , Traction/statistics & numerical data
5.
Arq. bras. med. vet. zootec ; 67(4): 961-968, July-Aug. 2015. tab
Article in Portuguese | LILACS | ID: lil-759233

ABSTRACT

Objetivou-se avaliar as implicações e os resultados obtidos frente aos tratamentos conservativo e cirúrgico em 37 cães sem distinção de sexo, raça ou idade, que apresentaram fraturas e luxações vertebrais (FLV) toracolombares. Cada paciente passou por anamnese, seguida por exames clínico, neurológico e radiográficos para se obter o diagnóstico neuroanatômico e a severidade da lesão. Os cães foram submetidos ao tratamento conservativo ou cirúrgico de acordo com as características de cada caso. Dos 37 animais deste estudo, 37,7% tinham percepção de dor profunda (PDP) intacta. Vinte animais foram submetidos ao tratamento conservativo, 14 ao tratamento cirúrgico e três animais faleceram antes do tratamento. Dos animais que mantiveram a PDP intacta, a taxa de recuperação foi de 100%, com tempo de recuperação total variando de sete a 75 dias, ao passo que, dos animais que perderam a PDP, nenhum recuperou a deambulação voluntária. Dos 14 animais operados, 42,8% apresentaram alterações vertebrais não visibilizadas ao exame radiográfico convencional, sendo necessária mudança na técnica cirúrgica planejada em 14,2% desses casos. Nos animais que mantiveram a PDP, não houve diferença significante nas taxas nem no tempo de recuperação da deambulação voluntária, independentemente do tipo de tratamento. Entretanto, houve diferença altamente significante entre os graus que mantiveram a PDP intacta com os animais que perderam a percepção de dor profunda em relação à taxa de recuperação. A taxa de eutanásia foi menor que em outros trabalhos descritos na literatura. Dos animais sem PDP submetidos ao tratamento conservativo ou cirúrgico, 31,25% readquiriram a capacidade de caminhar sem recuperar a PDP, sendo essa deambulação involuntária atribuída ao caminhar espinal.


Our aim of this paper was to study the implications and results associated with conservative and surgical treatment of dogs with thoracolumbar Vertebral fractures and luxations (VFL) so that the information obtained can be used to obtain guidelines that lead to greater recovery rates. For such, 37 dogs presenting VFL were examined, without distinction of sex, breed, or age. Each patient had detailed history obtained, followed by clinical, neurologic and radiographic exams for obtaining neuroanatomic location and severity of the nervous and vertebral lesions. The dogs were submitted to conservative or surgical treatment according to each case. Deep pain perception (DPP) was intact in 37.7% of the 37 dogs in this study. Twenty dogs received conservative treatment, 14 underwent surgery and three dogs died before treatment. Of the dogs with intact DPP, 100% recovered, with a recovery time varying between seven and 75 days, while none of the dogs that lost DPP recovered voluntary motion. Of the 14 dogs submitted to surgery, 42.8% had vertebral lesions that weren't detected using conventional radiography, which demonstrates the low sensitivity of this exam, and led to a need for a change in the planned surgical technique in 14.2% of these cases. In dogs with intact DPP there was no significant difference in time or rate of recovery of voluntary motion, regardless of the treatment method. However, there was a highly significant difference between the dogs which retained and lost DPP regarding recovery rates. The percentage of euthanasia was less than in other reports, probably due to the greater awareness and protectiveness of owners nowadays. Of the dogs without DPP treated either surgically or conservatively, 31.25% recovered ambulation without recovery of DPP, characterizing this ambulation as involuntary, attributed to spinal walk.


Subject(s)
Animals , Dogs , Fractures, Bone/diagnosis , Fractures, Bone/therapy , Fractures, Bone/veterinary , Spinal Injuries/diagnosis , Spinal Injuries/veterinary , Spinal Cord Injuries/diagnosis , Spinal Cord Injuries/veterinary , Paraplegia/veterinary , Radiography
6.
Arq. bras. med. vet. zootec ; 67(3): 655-663, May-Jun/2015. graf
Article in English | LILACS | ID: lil-753913

ABSTRACT

Intraoperative ultrasound (IOS) can provide details on various conditions of the spinal cord and vertebral canal. The aim of the present study was to evaluate the feasibility of using IOS in dogs undergoing spinal surgery and to describe the main findings. The vertebral canal of 21 dogs was examined with intraoperative ultrasonography: 13 underwent spinal surgery for removal of herniated intervertebral disc material, three for stabilization of vertebral fracture/luxation, two for removal of vertebral neoplasia, and three for cauda equina decompression. Particular attention was given to signs of cord compression. Intraoperative ultrasonography was feasible and useful in dogs undergoing surgery for spinal cord or cauda equina decompression and fracture stabilization. It was not paramount for locating the compression when this had been done via computed tomography (CT), but it showed alterations in spinal cord parenchyma not observed on CT and also confirmed adequate decompression of the spinal cord. The main advantages of intraoperative ultrasonography were estimation of vascularization and extent of spinal cord lesion. Most importantly, it allowed real time evaluation of the spinal cord and vertebral canal, which permits the modification of the surgical procedure.


A ultrassonografia intraoperatória pode fornecer detalhes sobre diversas condições da medula espinal e canal vertebral. O objetivo deste trabalho foi avaliar a viabilidade da utilização da ultrassonografia intraoperatória em cães submetidos à cirurgia espinomedular e descrever os principais achados. O canal vertebral de 21 cães foi examinado com ultrassonografia intraoperatória - 13 foram submetidos à cirurgia para remoção de material de disco herniado, três para estabilização de fratura/luxação vertebral, dois para remoção de neoplasia vertebral e três para descompressão de cauda equina. Atenção especial foi dada a sinais de compressão medular. A ultrassonografia intraoperatória foi viável e útil em cães submetidos a cirurgia para descompressão da medula espinal ou cauda equina e estabilização de fratura. Apesar de não ser indispensável para localização da compressão quando isso havia sido feito através de tomografia computadorizada (TC), demonstrou alterações no parênquima que não haviam sido observadas pela TC e confirmou a adequada descompressão da medula espinhal. As principais vantagens da ultrassonografia intraoperatória foram: estimar a vascularização e a extensão da lesão medular. Principalmente, permitiu uma avaliação em tempo real da medula espinal e do canal vertebral, o que permite modificação do procedimento cirúrgico.


Subject(s)
Animals , Dogs , Spinal Canal , Spinal Cord , Spinal Cord Injuries/veterinary , Ultrasonography, Interventional/veterinary , Decompression, Surgical/veterinary , Neurologic Examination/veterinary , Intraoperative Period , Ultrasonography, Doppler, Color/veterinary
7.
Arq. bras. med. vet. zootec ; 66(3): 787-796, 06/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-718094

ABSTRACT

Objetivou-se avaliar viabilidade, eficácia, vantagens e desvantagens da anestesia epidural lombossacral, junto à anestesia geral inalatória, em cirurgias de descompressão da cauda equina, tendo em vista que essas cirurgias são procedimentos longos e dolorosos. Para isso, foram utilizados 11 cães adultos com sinais clínicos de síndrome da cauda equina, que foram submetidos à anestesia geral inalatória e deixados no estágio anestésico mais superficial. Depois, realizou-se a anestesia epidural em seis dos 11 pacientes, por punção espinhal em L7-S1, com bupivacaína a 0,5 por cento. Os parâmetros fisiológicos (cardíacos, vasculares, respiratórios, temperatura corporal e glicemia) foram aferidos antes da medicação pré-anestésica, 10 minutos após esta, 30 minutos depois da epidural, depois da laminectomia, assim como após 60 minutos e 90 minutos da epidural, tanto no grupo com epidural como naquele sem esta (controle). Os animais que possuíam bloqueio epidural apresentaram redução significativa no consumo de anestésico inalatório e no tempo de extubação, não apresentando déficits neurológicos causados pela anestesia epidural, quando comparados com o grupo-controle. Conclui-se que a técnica de anestesia epidural é eficiente e vantajosa na realização de cirurgias descompressivas lombossacrais, pois proporciona menor risco anestésico para o animal...


The objective of this study was to evaluate the feasibility, effectiveness, advantages and disadvantages of lumbosacral epidural anesthesia with inhalational anesthesia in surgical decompression of the cauda equina, since this surgery has a lengthy and painful recovery from anesthesia. For this, 11 adult dogs which showed clinical signs of cauda equina syndrome were used. After the epidural, anesthesia in six of 11 patients, spinal tap in L7-S1, with bupivacaine 0.5 percent anesthetic was used. Physiological parameters (heart, vascular, respiratory and body temperature) were measured before, 10 minutes after, and 30 minutes after the epidural, after the laminectomia and 60 minutes and 90 minutes after the epidural, both in the epidural group and the control group. Animals that had ep showed a significant reduction in consumption of inhaled anesthetic and time of extubation. There were no neurological deficits caused by epidural anesthesia compared with the group without epidural anesthesia. It was concluded that the epidural anesthesia technique is effective in lumbosacral decompression surgeries, leading to a lower risk for the anesthetized animal...


Subject(s)
Animals , Dogs , Anesthesia, Epidural/veterinary , Anesthesia, Inhalation/veterinary , Dogs/surgery , Cauda Equina/surgery , Adjuvants, Anesthesia , Diazepam , Lumbosacral Region , Tramadol
8.
Arq. bras. med. vet. zootec ; 65(3): 649-653, June 2013. ilus
Article in Portuguese | LILACS | ID: lil-679093

ABSTRACT

Objetivou-se descrever a ocorrência de lesão iatrogênica meningomedular em um cão da raça Dachshund, macho, oito anos de idade, apresentando tetraparesia flácida há dois meses, que foi submetido à espondilectomia ventral para tratamento de extrusão crônica de disco intervertebral cervical. Durante remoção do material de disco herniado com removedores de tártaro e pinça hemostática, observou-se severa hemorragia dos seios venosos, descolamento meníngeo com laceração medular e imediata queda dos parâmetros cardiovasculorrespiratório, com evolução para a morte ante a ausência de respostas às medidas de ressuscitação cardiopulmonar.


Our objective was to describe the occurrence of an iatrogenic meningo-medullary lesion and the trans-surgical complications in an eight-year-old male Daschund, which presented flacid tetraparesis for two months, and underwent ventral spondylectomy to treat a chronic cervical intervertebral disc extrusion. During the removal of the herniated disc with dental picks and hemostatic forceps, we observed meningeal dislocation with medullary laceration and an immediate reduction in cardiovasculatory and respiratory parameters, which progressed to a cardiorespiratory arrest that was non-responsive to medication and finally led to the death of the patient.


Subject(s)
Animals , Dogs , Spine/anatomy & histology , Intervertebral Disc/anatomy & histology , Posture , Wounds and Injuries , Dogs
9.
Arq. bras. med. vet. zootec ; 65(3): 710-714, June 2013. ilus
Article in Portuguese | LILACS | ID: lil-679103

ABSTRACT

Poucos relatos têm descrito avulsões das cabeças lateral ou medial e avulsão bilateral das origens do músculo gastrocnêmio em cães e gatos. Este trabalho descreveu o primeiro relato de avulsão das origens lateral e medial do músculo gastrocnêmio em gata, bem como a técnica de reinserção cirúrgica. Uma gata, sem raça definida, com 10 anos, apresentou claudicação do membro posterior direito com postura plantígrada. Avulsão bilateral das cabeças do músculo gastrocnêmio foi diagnosticada com base nos achados do exame clínico. A técnica de reinserção foi realizada com fio mononáilon, numa sutura de Kessler modificada, ancorada em um orifício criado na porção metafisária distal do fêmur. Após período de imobilização externa complementar seguida de fisioterapia, houve recuperação satisfatória.


Few reports have described avulsions of the medial or lateral heads, as well as bilateral avulsion of the origins of the gastrocnemius muscle in dogs and cats. The objective of this study was to describe the first report of avulsion of the origins of the lateral and medial gastrocnemius muscle in a cat (Felis catus), as well as the surgical reinsertion technique. A mixed breed queen at 10 years of age presented claudication of the right hind limb with plantigrade stance. Bilateral avulsion of the heads of the gastrocnemius muscle was diagnosed based on findings from clinical a examination. The reinsertion technique was performed with monofilament nylon thread in a modified Kessler suture anchored in a hole created in the distal metaphyseal portion of the femur, obtaining satisfactory recovery after a period of additional external immobilization followed by physical therapy.


Subject(s)
Animals , Cats , Immobilization , Rupture , Achilles Tendon/anatomy & histology , Cats/classification
10.
Arq. bras. med. vet. zootec ; 65(1): 127-132, fev. 2013.
Article in Portuguese | LILACS | ID: lil-667546

ABSTRACT

Utilizou-se o eletroneuroestimulador como um meio adequado para confirmação do posicionamento da ponta de agulhas isoladas no espaço epidural lombossal, por meio de pequenas estimulações elétricas que provocam contrações dos músculos inervados, empregando-se agulha de cateter intravenoso em vez de agulha isolada para a eletroneuroestimulação. Foram utilizados 40 cães para procedimentos cirúrgicos ortopédicos, abdominais ou retroumbilicais que necessitassem de bloqueio epidural. Durante a introdução gradativa da agulha no canal vertebral lombossacral, estímulos elétricos de 1,5 a 0,5mA foram aplicados. Diante de contrações musculares em membros pélvicos, cauda e/ou ânus, as quais foram consideradas respostas condizentes com o correto posicionamento da agulha no espaço epidural, estimulando raízes da cauda equina, procedeu-se à administração da associação de lidocaína, bupivacaína e tramadol. Constatou-se a adequada anestesia epidural mediante relaxamento do esfíncter anal, ausência dos reflexos patelares e flexor e a analgesia na área cirúrgica abdominal. Conclui-se que o método foi eficaz para a confirmação do correto posicionamento da agulha no espaço epidural durante a realização dessa anestesia regional em cães.


The electric neurostimulator was used as an adequate mean for the confirmation of the correct placement of the tip of the insulated needles in the lumbosacral epidural space through small electric stimulations causing muscle contractions by using an intravenous catheter needle instead of an electric neurostimulation insulated needle. Forty dogs were selected based on the need for an epidural block for orthopedic, abdominal or retroumbilical surgical procedures. Electrical stimuli were applied from 1.5 to 0.5mA during a gradual introduction of the needle into the lumbosacral vertebral canal. Responses that were considered as indicative of the correct placement of the needle and stimulation of the cauda equina were muscle contractions in the pelvic limbs, tail or anus. An association of lidocaine, bupivacaine and tramadol was then administered. Adequate epidural anesthesia was confirmed through relaxation of the anal sphincter, absence of patellar and flexor reflexes and analgesia of the abdominal surgical area. The authors were able to conclude that the method used was effective to confirm the correct needle placement in the epidural space during regional anesthesia in dogs.


Subject(s)
Animals , Dogs , Needles , Needles/veterinary , Anesthesia, Epidural/trends , Anesthesia, Epidural , Anesthesia, Epidural/veterinary , Catheters , Catheters/veterinary , Electric Stimulation/instrumentation , Surgical Procedures, Operative , Surgical Procedures, Operative/veterinary
11.
Arq. bras. med. vet. zootec ; 65(1): 133-138, fev. 2013. ilus
Article in Portuguese | LILACS | ID: lil-667547

ABSTRACT

A luxação da articulação atlanto-occipital é considerada uma afecção incomum no homem e nos animais. Radiografias laterais são recomendadas para o diagnóstico. No entanto, estão sujeitas a erros relacionados ao ângulo de radiação, ao alvo da imagem, à distância e à sobreposição óssea. Objetivou-se neste relato descrever os achados clínicos e radiográficos de dois cães com luxação traumática da articulação atlanto-occipital que apresentavam tetraparesia, dor cervical cranial, incapacidade de elevar a cabeça e déficits de nervos cranianos. No primeiro animal, observaram-se deslocamento craniodorsal do processo articular do atlas em relação a um dos côndilos do occipital, ausência de sobreposição dos forames vertebrais laterais e sobreposição do côndilo do occipital ao processo articular do atlas, no lado direito, caracterizando uma luxação unilateral. No segundo animal, observou-se deslocamento craniodorsal dos processos articulares do atlas em relação aos côndilos do occipital, com sobreposição dos forames vertebrais laterais e ausência de visibilização dos côndilos do occipital em virtude da projeção cranial dos processos articulares do atlas em direção ao crânio, caracterizando luxação bilateral. Conclui-se que o exame radiográfico simples, nas projeções laterolateral e ventrodorsal, apesar da dificuldade de ser interpretado, é eficiente para confirmar o diagnóstico da luxação atlanto-occipital traumática, tanto a simétrica quanto a assimétrica.


Atlanto-occipital luxation is considered rare in both humans and animals. Lateral radiographs are recommended for diagnosis, however, errors may occur related to the angle of radiation, image target, distance and overlapping of bone. Our objective is to report the clinical and radiographic findings in two dogs with traumatic atlanto-occipital luxation, which had tetraparesis, cranial neck pain, and inability to raise the head and cranial nerve deficits. The first animal had a cranio-dorsal dislocation of the articular process of the atlas in relation to one of the occipital condoles, with no overlapping of the transverse foramens or overlapping of the occipital condile in relation to the articular process of the atlas, on the right side, which characterizes a unilateral luxation. The second animal presented with a cranio-caudal dislocation of the articular processes of the atlas regarding the occipital condoles, with overlapping of the transverse foramens and inability to visualize the occipital condoles due to the cranial advancement of the articular processes of the atlas towards the skull, which characterizes a bilateral luxation. We conclude that a simple radiographic exam, in lateral and ventrodorsal projections, though difficult to interpret, is efficient in confirming a diagnosis of traumatic atlanto-occipital luxation, both symmetric and asymmetric.


Subject(s)
Animals , Dogs , Dogs/abnormalities , Diagnostic Techniques, Neurological , Diagnostic Techniques, Neurological/veterinary
12.
Arq. bras. med. vet. zootec ; 63(1): 61-66, Feb. 2011. ilus
Article in Portuguese | LILACS | ID: lil-582325

ABSTRACT

Relatou-se a ocorrência de fratura patelar associada à ruptura do tendão patelar em um cão sem raça definida, macho, atendido em um hospital veterinário escola. A técnica utilizada foi a combinação de fixação óssea com fio de Kirschner e aplicação de banda de tensão, recomendada em fraturas transversais da patela. Para reparar a lesão do tendão patelar, realizou-se a sutura tipo Kessler modificada com fio de náilon 0,80mm. No retorno do paciente, 150 dias após o procedimento cirúrgico, havia processo cicatricial ósseo avançado da patela. Concluiu-se que as medidas adotadas para reparação da lesão foram eficazes.


It is reported the occurrence of patellar fracture associated with rupture of the patellar tendon in a mongrel male dog referred to a Teaching Veterinary Hospital. The used technique was the combination of bone fixation with Kirschner wire and application of tension band recommended in most transverse fractures of the patella. To repair the damage to the patellar tendon, the modified Kessler suture with nylon 0.80mm was performed. When the patient returned 150 days after surgery, advanced bone healing process was observed in patella. It was concluded that the measures taken to repair the injury were effective.


Subject(s)
Animals , Dogs/classification , Fractures, Bone , Patella/anatomy & histology , Wounds and Injuries/veterinary , Rupture/complications , Tendons/anatomy & histology
SELECTION OF CITATIONS
SEARCH DETAIL